"User registration" is required to download our catalogues.
"*User registration is required to download.
Nonmembers can register.
Log in here or register for user registration.
Registered users can download our electronic catalog (PDF), 2D-CAD data (DXF) ,
3D-CAD data (STEP, IGES), and field network device profile (GSD)."
TG2400M
■Any orientation
■Compact size
■Energy-saving
■Quick starts and stops
■Maintenance call
■Vibration free
■Model coupling free
■Automatic calibration
■High throughput
■Rotational speed control
■Serial communication
■Safety standards certification for NRTL SEMI-S2 CE
Application
■ Semiconductor production
■ Electronics gun exhaust, ionization source exhaust
■ FPD manufacturing
■ Surface treatment, surface modification
■ Manufacture of various electronic components
■ Analysis, testing equipment
■ Lamp production, optical components production
■ Accelerating device, radiation facility, nuclear fusion research
■ Heat treatment
■ Research and development
Specifications
Inlet flange |
VG250 ISO-B250 |
|
Volume flow rate |
N2 (L/s) |
2400 |
N2 screen) (L/s) |
2300 |
|
H2 (L/s) |
1100 |
|
Max. compression ratio |
N2 |
1×108 |
H2 |
1.5×103 |
|
Base pressure |
VG・ISO-B (Pa) |
<1×10-6 |
VG・ISO-B(Torr) |
<7.5×10-9 |
|
Max. throughput※1 |
N2 (sccm) |
3000 |
Startup time |
(min) |
4~5 |
Shutdown time |
(min) |
4~5 |
Max. backing pressure |
(Pa / Torr) |
200 / 1.5 |
Recommended backing vacuum pump |
(L/min) |
≧500 |
Position |
Any orientation |
|
Weight (kg) VG・ISO-B |
34 / 42 |
|
Controller |
TC010MA |
|
Special specifications *Contact our sales representative for |
-Chemical-use |
*1 : When using a backing vacuum pump of 1000L/min.
[Ambient temperature for use]
The ambient temperature range to ensure you reach the ultimate pressure is 10-23℃. The permissible ambient temperature is 10-32℃ for air cooling type and 10-40℃ for water cooling type. The maximum temperature for the cooling water which ensures the ultimate pressure is 30℃ and the allowable temperature range for cooling water is 10-35℃.
[Corresponding gases]
Some types of gas to be evacuated may damage the pump.
Contact Osaka Vacuum for a list of applicable gas types.
Drawing of outside dimensions
Ⓐ | Ⓑ | Ⓒ | Ⓓ |
VG250 | φ350 | 16 | 340 |
ISO-B250 | φ335 | 16 | 340 |
Performance curve
Controller
Controller model |
TC010MA |
Input Voltage (ACV) |
200-240(±10%) |
Input Frequency (Hz) |
50/60 |
Input Phases |
Single |
Input Power (VA) |
1200 |
Rated Output Frequency (Hz) |
520 |
Weight (kg) |
11 |
Standard accessories |
-Input cable (5m): 1 -Remote connector: 1 -Manual (Instruction, Serial communication instruction): 1 copy |
TMP |
TG2400M |