Global Small Medium Large
Osaka Vacuum, Ltd.
Home | News Releases | Events
 

RD302

Inlet flange
80A JISB2290VF
Nominal volume flow rate*1 (m3/h)
50Hz 
250
60Hz 
300
Allowable pressure difference (kPa)
50Hz 
9.3
[When using a standard motor]
60Hz 
8
Ultimate pressure (Pa)
Back pump single-stage RP
7x10-2
Back pump 2-stage RP
1.3x10-2
Volume flow rate of standard backing pump (m3/h)
36~100
Rotation speed (r/min)
50Hz
3000
60Hz
3600
Standard motor output (kW)
1.5
Oil capacity (L)
0.9
Cooling water consumption*2 (m3/h)
Air cooling
Weight (kg)
With totally enclosed fan cooling motor
110
No motor
80
  • *1 : The effective volume flow rate varies according to the backing pump. For details, contact our sales representative.
  • *2 : Maximum cooling water temperature should be 30℃.
  • -Allowable ambient temperature: 10 to 40℃ during operation, -5 to +60℃ in storage.
  • -Drain water before storing to prevent freezing over.
RD302Drawing of Outside dimension

Zoom Clicking the "Zoom" button opens the file in Acrobat Reader. Print from the PDF.

  • Reprinting prohibited without permission. Contents are subject to change without notice.
Contact Inquiry Form User Registration Downloads
Google

Site Search


Click here to download Adobe Flash Player.

Adobe Flash Player

Click here to download Adobe Reader.

Adobe Reader
Sitemap | Personal Privacy Protection Policy | Copyright | About This Site