RD2500/RD2510

Model
RD2500
RD2510
Inlet flange
200A JIS10KFF
Nominal volume flow rate*1 (m3/h)
50Hz 
2070
60Hz 
2500
Allowable pressure difference (kPa)
50Hz 
6.7
19
[When using a standard motor]
60Hz 
5.3
15
Ultimate pressure (Pa)
Back pump single-stage RP
7x10-2
Back pump 2-stage RP
1.3x10-2
Volume flow rate of standard backing pump (m3/h)
450~600
Rotation speed (r/min)
50Hz
1500
60Hz
1800
Standard motor output (kW)
5.5
15
Oil capacity (L)
6.2
Cooling water consumption*2 (m3/h)
0.4
Weight (kg)
With totally enclosed fan cooling motor
670
No motor
620
  • *1 : The effective volume flow rate varies according to the backing pump. For details, contact our sales representative.
  • *2 : Maximum cooling water temperature should be 30℃.
  • -Allowable ambient temperature: 10 to 40℃ during operation, -5 to +60℃ in storage.
  • -Drain water before storing to prevent freezing over.
RD2500Drawing of Outside dimension

Zoom Clicking the "Zoom" button opens the file in Acrobat Reader. Print from the PDF.

  • Reprinting prohibited without permission. Contents are subject to change without notice.